HANLA LMS 
VESSEL:  LOAD MONITORING SYSTEM

PORT:  MEDAN

JOBNO :20140102
EQUIPMENT:

LOAD MONITORING SYSTEM (LMS)

 

DATE:24.01.2014

MAKE:  HANLA

MODEL: SPT-2000S-3T | DIR M1600

LOAD MONITORING SYSTEM (LMS)

Hanla Load Monitoring system LMS offers complete solutions for tank monitoring and alarming. The system sends readings from all tanks and lines onboard to user-friendly LOADING COMPUTER software.

DEFECTS/REASON FOR CALL:  INSPECTION AND HEALTH CHECK

ITEM

DESCRIPTION

REMARKS

1

HANLA SPT 2000

JOB REQUISITION :

 

Requested to carry out inspection and health check of Cargo Monitoring System.

 

Check defect and propose recommendation.

 

2

Load monitoring system (LMS)

INSPECTION IN CCR :

 

Checked the COT system, found not working.

DIR M1600 Multi Monitor unstable and showing error.

Individual DIR 700 displayed error readings.

3

spt 2000 sensor

 

HANLA

INSPECTION ON DECK

 

Inspectedall the Transmitters and sensors including float one by one.

 

Sensors - some of the sensors found full of water inside.

 

PCB card: All PCB settings wrong configuration. Some PCBs are faulty.

4

HANLA      HANLA

 

CONCLUSION

 

Complete system out of order. DIR M1600 is obsolete and no longer supported.

System need to be upgraded to new

 

 

 

 

 

Copyright © 2016 raycOntrol pte ltd. All rights reserved. All brands and product names are trademark of their respective owners. raycOntrol pte ltd assumes no responsibility or liability for any misinterpretation, loss or damage incurred as a result of any use of the information and material contained within or downloaded from this website. All parties concerned are encouraged to conduct their own information verification or confirmation.