6S issue was resolved by changing settings in the system configuration..

 

 

LOOSE CONNECTIONS, WORNED CABLE PROTECTIONS.

 

Found cables were loose and protection worned. Possibility for water ingress into sensor.">

VESSEL :

ENRAF MARINE RADAR EM540

 

PORT : SG ANCHORAGE

JOBNO :20150927

EQUIPMENT :  CARGO TANK  MONITORING SYSTEM

DATE :

MAKE : ENRAF MARINE RADAR

MODEL :  EM540 WATER INGRESS

ITEM

DESCRIPTION / REMARKS :

1

JOB DESCRIPTION:

 

To check and troubleshoot #1P & 3P Radar gauges communication Error due to liquid damage.

 

EM540

 

TROUBLESHOOTING:

 

Checked the system found communication problem on 1P ,3P,5P & 6S.

 

Erratic signals coming from sensors.

 

 

 

 

 

 

 

 

 

 

 

 

 

2

CHECK AND CLOSE INSPECTION OF SENSORS

 

Found sensors liquid damage. (1P, 3P).

 

WATER INGRESS

 

HANLA EM540

 

 

 

 

 

 

 

 

ANNUAL CERTIFICATION

 

 

Badly corroded PCB board.

 

 

 

REPAIR

3

RADAR ADDRESS CONFLICT:

 

6S issue was resolved by changing settings in the system configuration..

 

4

LOOSE CONNECTIONS, WORNED CABLE PROTECTIONS.

 

Found cables were loose and protection worned. Possibility for water ingress into sensor.

 

CHECKFUNCTION TEST

 

RECOMMENDATION:

 

1P, 3P and 5P sensors and cable protections to renew.

Cable Gland and Gasget renew for all the radar.

REPORTED BY

Arunkumar

 

 

 

 

 

 

 

Copyright © 2016 raycOntrol pte ltd. All rights reserved. All brands and product names are trademark of their respective owners. raycOntrol pte ltd assumes no responsibility or liability for any misinterpretation, loss or damage incurred as a result of any use of the information and material contained within or downloaded from this website. All parties concerned are encouraged to conduct their own information verification or confirmation.