LOOSE CONNECTIONS, WORNED CABLE PROTECTIONS.
Found cables were loose and protection worned. Possibility for water ingress into sensor.">
PORT : SG ANCHORAGE
JOBNO :20150927
DATE :
01.10.2015
MAKE : ENRAF MARINE RADAR
MODEL : EM540 WATER INGRESS
ITEM
DESCRIPTION / REMARKS :
hanla.raycontrol.com
1
JOB
DESCRIPTION:
TROUBLESHOOTING:
Erratic signals coming from sensors.
2
CHECK AND CLOSE INSPECTION OF SENSORS
Found sensors liquid damage. (1P, 3P).
Badly corroded PCB board.
3
RADAR ADDRESS CONFLICT:
6S issue was resolved by changing settings in the system configuration..
4
LOOSE CONNECTIONS, WORNED CABLE PROTECTIONS.
Found cables were loose and protection worned. Possibility for water ingress into sensor.
RECOMMENDATION:
1P, 3P and 5P sensors and cable protections to renew.
Cable Gland and Gasget renew for all the radar.
REPORTED BY
Arunkumar
Copyright © 2016 raycOntrol pte ltd. All rights reserved. All brands and product
names are trademark of their respective owners. raycOntrol pte ltd assumes no
responsibility or liability for any misinterpretation, loss or damage incurred
as a result of any use of the information and material contained within or
downloaded from this website. All parties concerned are encouraged to conduct
their own information verification or confirmation.
|