VESSEL: LOAD MONITORING SYSTEM |
PORT: MEDAN |
JOBNO :20140102 |
||
EQUIPMENT: LOAD MONITORING SYSTEM |
DATE:24.01.2014 |
|||
MAKE: HANLA |
MODEL: SPT-2000S-3T |
|||
DEFECTS/REASON FOR CALL: INSPECTION AND HEALTH CHECK |
||||
ITEM |
DESCRIPTION |
REMARKS |
||
1 |
|
JOB REQUISITION :
Requested to carry out inspection and health check of Cargo Monitoring System.
Check defect and propose recommendation.
|
||
2 |
|
INSPECTION IN CCR :
Checked the COT system, found not working. DIR M1600 Multi Monitor unstable and showing error. Individual DIR 700 displayed error readings. |
||
3 |
|
INSPECTION ON DECK
Inspectedall the Transmitters and sensors including float one by one.
Sensors - some of the sensors found full of water inside.
PCB card: All PCB settings wrong configuration. Some PCBs are faulty. |
||
4 |
|
|||
|
CONCLUSION
Complete system out of order. DIR M1600 is obsolete and no longer supported. System need to be upgraded to new |
|||