MMCU-500

     HANLA CARGO MONITORING SYSTEM MMCU-500

VESSEL: HANLA  MMCU-500

PORT: SG ANCHORAG

JOBNO :20130527/20130425

EQUIPMENT:CARGO M ONITORING SYSTEM MMCU-500

DATE: 17/05/13

MAKE: HANLA

MODEL:MMCU-500

MMCU-500 Communication Unit

DEFECTS/REASON FOR CALL: REPAIR ,REINSTALL AND CONFIGURE THE MMCU-500

ITEM

DESCRIPTION

REMARKS

1

HANLA ENRAF HONEYWELL MMCU-500 communication unit

JOB DESCRIPTION :

 

To repair reinstall and reconfigure the MMCU 500 unit.

 

2

MMCU-500

SIL 200 UNIT FAULTY :

 

After full inspection, check and suspected the SIL 200 unit in MMCU faulty.

3

MMCU-500

MMCU FACTORY REPAIR :

 

Removed the MMCU 500 unit from vessel and off landed to our w/shop.

 

MMCU 500 sends to Korea Factory to replace the SIL 200 unit and thorough checking for any other faults.

 

 

4

MMCU-500

REINSTALL THE MMCU 500 :

 

After renewed the SIL 200 unit, reinstall back to vessel.

 

Reprogram system and  configuration settings for every tanks.

5

MMCU-500

MMCU-500

SYSTEM RECONFIGURATION

 

Reconfigured port and communication settings.

 

System found working in order to the satisfaction of C/O and Captain.

 

 

 

 

 

 

Copyright © 2016 raycOntrol pte ltd. All rights reserved. All brands and product names are trademark of their respective owners. raycOntrol pte ltd assumes no responsibility or liability for any misinterpretation, loss or damage incurred as a result of any use of the information and material contained within or downloaded from this website. All parties concerned are encouraged to conduct their own information verification or confirmation.