VESSEL : HANLA Optima Plus Sensor |
PORT : SG ANCHORAGE |
JOBNO :20140909 |
||
|
EQUIPMENT :FIXED GAS SAMPLING |
DATE : 22/09/14 |
|||
|
MAKE :HANLA |
MODEL : HGS 100 |
|||
|
ITEM |
DESCRIPTION / REMARKS : TROUBLESHOOTING AND CALIBRATION |
|||
|
1 |
|
DEFECT REPORT :
Hc sensor for ballast out of function.
Checked the sensor found faulty. |
||
|
2 |
|
Renewed New Hc Optima Plus Sensor for Part1 Ballast. |
||
|
3 |
|
After Renewed The Sensor, Calibrated By Sampling Gas And Found Working Satisfactory |
||
|
4 |
|
Chief requested to check pump room HC,H2S and O2 sensor.
Checked found sensor out of setting. |
||
|
5 |
|
Calibrated All Three Sensor Of Pump room.
Now system running with no alarm fault working Satisfactory |
||