VESSEL : PL3700 PRESSURE TRANSMITTER |
PORT : SINGAPORE |
JOBNO :20151011 |
||||||||||||||||||||||
EQUIPMENT : REMOTE SOUNDING SYSTEM / FIXED GAS SYSTEM |
DATE : 12/10/2015 |
|||||||||||||||||||||||
MAKE : HANLA | ENRAF | HONEYWELL |
MODEL : PL 3700 |
|||||||||||||||||||||||
The PL3700 family of pressure transmitters includes submersible, flange-mounted, and manifold sensors that measure level in tanks (service tanks, ballast tanks, slop and water) and the pressure on cargo lines. In addition, it also includes an atmospheric pressure sensor for level calculations. All transmitters feature a ceramic, capacitive sensor that ensures best-in-class reliability and corrosion resistance. Application in Hanla Draft, Water Ballast Tank and Cargo tanks. | ||||||||||||||||||||||||
ITEM |
DESCRIPTION / REMARKS : |
|||||||||||||||||||||||
1 |
JOB DESCRIPTION :
aa. HGS-100 :- To check fixed gas sampling system bb. PL 3700 :- To check faulty WBT and Draft Remote gauging.
|
|||||||||||||||||||||||
2 |
HGS-100 INSPECTION OF FIXED GAS SYSTEM
Inspected the system, found all the setting parameters and configurations corrupted.
|
|||||||||||||||||||||||
3 |
RECONFIGURE SETTINGS
Proceed to carry out reconfiguration and reset all channels one by one.
Found several alarms persist.
Troubleshoot and found 02 nos sampling pumps faulty.
* System cannot be tested further to see if there are any other issues until pumps are renewed.
* Note system is not operational.
|
|||||||||||||||||||||||
4 |
PL 3700 WBT AND DRAFT GAUGE
Check reported faulty Tank Gauges. WBT 1P, 6P, APT (P/S) and 04 Nos draft gauges erratic readings .
TROUBLESHOOT AND FOUND
|
|||||||||||||||||||||||
5 |
RECTIFICATION
#1 WBT (P)
Swapped 6 P WBT PCB to 1P , configured settings. Working in Order.
Draft Mid P / S:
Adjust and calibrated. Tested working satisfactory.
|
|||||||||||||||||||||||
6 |
RECOMENDATION /REQUIRED SPARES:
PCB – 06 Nos SENSOR– 02 Nos Samplimg pump for Fiexd Gas Sampling System – 02 Nos
|
|||||||||||||||||||||||
/nbsp; /nbsp; /nbsp; /nbsp; /nbsp; /nbsp; Copyright © 2016 raycOntrol pte ltd. All rights reserved. All brands and product names are trademark of their respective owners. raycOntrol pte ltd assumes no responsibility or liability for any misinterpretation, loss or damage incurred as a result of any use of the information and material contained within or downloaded from this website. All parties concerned are encouraged to conduct their own information verification or confirmation. |
||||||||||||||||||||||||