VESSEL : TANK OVERFILL ALARM |
PORT : CHINA |
JOBNO :20141238 |
|
EQUIPMENT : CARGO TANK MONITORING SYSTEM |
DATE : 03.02.2015 |
||
MAKE : HANLA |
MODEL : TLP 100 |
||
TLP 100 The TLP-100, LIQUID LEVEL is the newest version of magnetic float level gauge for marine tankers which has been developed based on the long time field experience. The detection of float position is conducted by Hall IC elements to eliminate problem of contact fusing and/or accuracy failure caused by existing reed switch system. |
|||
ITEM |
DESCRIPTION / REMARKS : |
||
1 |
JOB DESCRIPTION:
To health check and calibrate the cargo tank level gauges,pressure & temp transmitter, And level alarm system(each 16 nos).
|
||
2 |
RENEW PRESS SENSOR : Found 5s pressure sensor was faulty Sensor Disconected and renewed press sensor from ship supply
|
||
4 |
PRESSURE AND TEMP TRANSMITTER:
Checked and set compensation value as per actual value .
|
||
5 |
HIGH AND OVERFILL ALARM FUNCTION TEST :
Checked all cargo tank high and overfill alarm by manually activating the test device.
|
||
6 |
VECS :
To Health check and calibrate VECS monitoring system System showing error
|
||
|
TROUBLE SHOOTING :
Found O2 Sensor and filter regulator faulty |
||
|
RENEWED PARTS : Renewed O2 sensor and filter regulator with supply from ship.
Calibrated system working satisfactory
|
||
|
RECOMMENDATION:
FOUND BELOW LISTED ITEMS ARE FAULTY. RECOMMENDED TO RENEW.
1.VECS Recommented to renew sensing line. 2 Pressure transmitter to renew. |
||
Copyright © 2016 raycOntrol pte ltd. All rights reserved. All brands and product names are trademark of their respective owners. raycOntrol pte ltd assumes no responsibility or liability for any misinterpretation, loss or damage incurred as a result of any use of the information and material contained within or downloaded from this website. All parties concerned are encouraged to conduct their own information verification or confirmation. |
|||