VESSEL : TRIM GAUGE |
PORT : SINGAPORE |
JOB NO :20160912 |
|
EQUIPMENT : HANLA TRIM GAUGE |
DATE : 09.12.2016 |
||
MAKE : HANLA |
MODEL : CT-180 |
||
TRIM GAUGE Tank gauging system display actual draft values for all points monitored. Angular inclination can be measured in two planes, trim and heel, by the use of one or two solid state inclinometers mounted within the superstructure or taken from the draft gauge signal and can be displayed on the ship’s bridge or similar. |
|||
ITEM |
DESCRIPTION / REMARKS: |
||
1 |
JOB DESCRIPTION :
Checking and rectification of Trim gauge. Checked TRIM Gauge found Leaking on indicator and connecting fittings.
|
||
2 |
RECTIFICATION:
Tighten and rectified leakage on Indicator, fitting and deck sensing line. Calibration with our precision calibrator.
After calibration installed in position and tested with actual signal working satisfactory.
|
||
3 |
OIL CONTAMINATION IN TRANSMITTER PANEL
Further checking found Transmitter Panel for Draft, Ballast and HFO are badly contaminated with oil. This will give rise to reading errors.
|
||
4 |
Recommendation:
Due to very bad oil contamination. Recommended to service all the components in the panel. As Trim Gauge signals are taken from this panel it may result in error in near future.
|
||
Copyright © 2016 raycOntrol pte ltd. All rights reserved. All brands and product names are trademark of their respective owners. raycOntrol pte ltd assumes no responsibility or liability for any misinterpretation, loss or damage incurred as a result of any use of the information and material contained within or downloaded from this website. All parties concerned are encouraged to conduct their own information verification or confirmation. |
|||