VESSEL: VAPOUR MONITORING SYSTEM

PORT: SG

JOBNO :20140508

EQUIPMENT: VAPOUR MONITORING SYSTEM

DATE:20/05/2014

MAKE: HANLA

MODEL: HDI 200

ITEM

DESCRIPTION / REMARKS :

1

JOB DESCRIPTION /DEFECT REPORTED :

 

Inspected and troubleshoot oxygen/vapour monitoring system for error reading.

 

 

 

 

 

 

 

 

 

2

FUNCTION TEST / TROUBLESHOOT :

 

Inspected system and found all regulator,detector panel and flow meter working in order.

Checked monitoring panel and found input parameter settings wrong.

 

 

 

3

CARRIED OUT SETTINGS:

 

Carried out correct parameter settings on panel.

Calibrated system according to its high level and low level for vapour monitoring, high level for oxygen and non flow detection.

 

 

 

 

4

 

FINAL TEST

 

Final tested system and checked its alarm for high level and low level working satisfactory to vessel chief engineer

 

 

 

RECOMMENDED

 

To renew VAPOUR PRESS INDICATOR found defective.