VESSEL : HANLA VRC |
PORT : ANCHORAGE |
JOBNO :20150231 |
||
EQUIPMENT : VRC |
DATE : 10.03.15 |
|||
MAKE : HANLA |
MODEL : AV-CWR WAFER |
|||
VALVE REMOTE CONTROL Valve Remote Control System (VRCS) is a complete system for valve management and control on all types of ships. Together with the gauging system, it provides a comprehensive solution for fluid control. The Hydraulic VRCS is the best choice for installation locations, like on deck, submerged or explosive areas. The system covers a wide range of actuators, both quarter-turn and linear with compact and robust design covering the majority of marine valves. The system is engineered specifically with the characteristics of life at sea in mind. |
||||
ITEM |
DESCRIPTION / REMARKS : |
|||
1 |
JOB DESCRIPTION :
Troubleshoot for VRC system 1. Valve of No.1 Cargo Hold bilge well (Pside) damage. 2. No.1 & No.2 Hyd. Gear Pump HPU not working.
|
|||
2 |
1. Valve of No.1 Cargo Hold bilge well (Pside) damage.
|
As requested, supplied 10 Nos Bypass Valves
|
||
3 |
2. No.1 & No.2 Hyd. Gear Pump HPU not working.
SYSTEM CHECKING :
#01 pump pressure satisfactory. AUTO mode is not working. Carried out settings to Relief , Reducing valve and Pressure switches. Tested working satisfactory to Vessel Engineer.
|
|||
3 |
Tested #02 Max pressure only 10 bar. Dismantle for checking. Found gear pump worn out. Recommend to renew.
|
|||
Copyright © 2016 raycOntrol pte ltd. All rights reserved. All brands and product names are trademark of their respective owners. raycOntrol pte ltd assumes no responsibility or liability for any misinterpretation, loss or damage incurred as a result of any use of the information and material contained within or downloaded from this website. All parties concerned are encouraged to conduct their own information verification or confirmation. |
||||
|