VESSEL: LUCAS |
PORT: SINGAPORE |
JOBNO :20140232 |
|
EQUIPMENT: CARGO MONITORING SYSTEM |
DATE:03.03.2014 |
||
MAKE: HANLA |
MODEL: TMR-702T |
||
DEFECTS/REASON FOR CALL: ERROR READING ON 1P CARGO TANK |
|||
TMR SERIES - 702T
Reed switch type
float level switches have a magnet built in
|
|||
ITEM |
DESCRIPTION / REMARKS |
||
1 |
JOB DESCRIPTION: Inspect and Troubleshoot the 1P cargo tank.
|
||
2 |
INITIAL INSPECTION: Checked the PCB card reading and actual reading are mismatched. Found parameter setting was wrong.
|
||
3 |
PARAMETER SETTING:
ZERO and SPAN adjustment was done as per the UTI and HANLA specification table. After the setting run the system and compared the reading. System working in order checked and satisfied by C/O.
|
||
4 |
HIGH LEVEL & OVER FILL ALARM NOT WORKING:
Ship officer requested to check level alarms. Checked one by one found 4P sensor full of water and rusted. Recommended to change the sensor.
Sensor details: Make: HANLA ;Model:TMR-702T ;SERIAL NO:970406 |
||
Copyright © 2016 raycOntrol pte ltd. All rights reserved. All brands and product names are trademark of their respective owners. raycOntrol pte ltd assumes no responsibility or liability for any misinterpretation, loss or damage incurred as a result of any use of the information and material contained within or downloaded from this website. All parties concerned are encouraged to conduct their own information verification or confirmation. |
|||